RCW/RAW SERIES DOUBLE EFECT ABSORPTION CHILLER This chiller achieves superb energy efficiency at all operating range, from the rated load to. absorption chillers featuring stai .. The absorption chiller is designed in accordance wilh JIS B 5. OYantai Ebara Air Conditioning Equipment Co., Ltd. Chiller-Heater operating time. absorber. Direct Fired Absorption Chiller-Heater ol equipped with latest OYantai Ebara Air Conditioning Equipment Co., Ltd.

Author: Malalmaran Tashura
Country: Montenegro
Language: English (Spanish)
Genre: Relationship
Published (Last): 13 April 2011
Pages: 105
PDF File Size: 20.50 Mb
ePub File Size: 4.83 Mb
ISBN: 896-8-54672-692-9
Downloads: 79744
Price: Free* [*Free Regsitration Required]
Uploader: Bakinos

Inspecting safety devices The operation and display of safety devices and thermosensors are inspected.

Absorption Chiller / Heaters

To ensure optimal performance, we conduct maintenance work in our specialized fields. After the completion of individual inspections, the equipment is test run in the actual operating environment to check temperatures and pressures of respective parts and to comprehensively check the operation status.

  AVL 6211 PDF

The performance of the vacuum pump purge pump is checked. The absorbent is sampled and analyzed for chemical composition to determine the inhibitor content and alkalinity.

On-season servicing replaces daily inspection performed by customers with the manufacturer evaluating the operation status. Analyzing the absorbent The absorbent is sampled and analyzed for chemical composition to determine the inhibitor content and alkalinity. Control panel circuits are inspected.

Account Suspended

Also, the operation of electromagnetic contactors, auxiliary relays, and timers is checked. This work is intended to maintain heat transfer efficiency and to remove contaminants that cause corrosion.

Test running After the completion of individual inspections, the equipment is test run in the actual operating environment to check temperatures and pressures of respective parts and to comprehensively check the operation status.

Equipment with an intelligent control panel is checked for the proper functioning of each component.

A suitable inspection plan designed for your operational needs ensures efficient operation and provides cost reduction. The inner surface of the evaporator cooler tube is washed chillr water and scrubbed with a bristle brush.

  CCPS LOPA PDF

This work is intended to maintain the heat transfer efficiency and to remove contaminants that cause corrosion. Cleaning the chilled water evaporator tube The inner surface of the evaporator cooler tube is washed with water and scrubbed with a bristle brush.

If required, the equipment is overhauled to restore the pump to optimal performance. Skip To Content Search Site map. Servicing electric components Control panel circuits are inspected. If required to maintain proper characteristics, the solution composition is adjusted by adding the inhibitor or alkalinity adjustment agent.